Enforce sensor range for temperature target (#18465)
* Mitigate stepper timeout * Add CHAMBER PWM code * Structured thermistor tables * Fix reversed sensor ranges * Prevent temps outside sensor range
This commit is contained in:
@@ -24,7 +24,7 @@
|
||||
|
||||
// 100k bed thermistor with a 10K pull-up resistor - made by $ buildroot/share/scripts/createTemperatureLookupMarlin.py --rp=10000
|
||||
|
||||
const short temptable_99[][2] PROGMEM = {
|
||||
const temp_entry_t temptable_99[] PROGMEM = {
|
||||
{ OV( 5.81), 350 }, // v=0.028 r= 57.081 res=13.433 degC/count
|
||||
{ OV( 6.54), 340 }, // v=0.032 r= 64.248 res=11.711 degC/count
|
||||
{ OV( 7.38), 330 }, // v=0.036 r= 72.588 res=10.161 degC/count
|
||||
|
||||